| Product data | Type | Format | Estimated volume | Continuous generation | Real-time generation | Access information |
|---|---|---|---|---|---|---|
Operational data: Cumulative | These counters typically increment and persist over the long term. They might reset only upon major component replacement or complete system overhaul. Examples: | Numerical values. Individual 32-bit Unsigned Integers (binary). Examples of units: Seconds, meters. | 240 bytes per retrieval. | Yes. Values are generated continuously in the sense that its value is updated and stored whenever the hoist is used. | No. Value is updated and stored only when the hoist is used. | Data is accessible over the HMI embedded into the condition monitoring unit. It is also available in YKC if TRUCONNECT gateway is included in the rope hoist product. |
Operational data: Cyclic/Event-Based | Individual operations or recent, specific events. Often, this data might be logged per cycle or when a significant change occurs. Examples: | Numerical values. Individual 32-bit Unsigned Integers (binary). Real. Examples of units: Kilograms. | 12 bytes per retrieval. | Yes. Values are generated continuously in the sense that its value is updated and stored whenever the hoist is used. | No. | Data is accessible over the HMI embedded into the condition monitoring unit. It is also available in YKC if TRUCONNECT gateway is included in the rope hoist product. |
Operational data: Real time measurements | Load. Position of the hook. Speed. | Numerical values. Individual 32-bit Unsigned Integers (binary). Examples of units: Kilograms. | 56 bytes per retrieval. | Yes. Values are updated and stored continuously. | Yes. Values are updated and stored continuously, in a real-time. | Data is accessible over the HMI embedded into the condition monitoring unit. |
Health & Performance Indicators (Derived/Aggregated) | These often provide more actionable insights by aggregating or processing the raw operational data. Examples: | Numerical values. Individual 32-bit Unsigned Integers (binary). Percentage. | 32 bytes per retrieval. | Yes. Values are generated continuously in the sense that its value is updated and stored whenever the hoist is used. | No. Value is updated and stored only when the hoist is used. | Data is accessible over the HMI embedded into the condition monitoring unit. It is also available in YKC if TRUCONNECT gateway is included in the rope hoist product. |
Environmental data | Ambient temperature extremes (min/max). Continuous measurements. | Numerical values. 32-bit Unsigned Integer (binary). Examples of units: | 24 bytes per retrieval. | Yes. Continuous for extremes, when extreme values are exceeded. | Yes. Real-time for the continuous measurements coming from the sensors. | Data is accessible over the HMI embedded into the condition monitoring unit. Part of it is also available in YKC if TRUCONNECT gateway is included in the rope hoist product. |
Fault/event data | Fault log. | 32-bit Unsigned Integer (binary). | 240 bytes per retrieval. | Yes. Values are generated continuously in the sense that its value is updated and stored whenever the fault or event occurs. | No. | Data is accessible over the HMI embedded into the condition monitoring unit. It is also available in YKC if TRUCONNECT gateway is included in the rope hoist product. |